357457

7680Wh PowerWall

Residential ESS

iSPACE uses the latest technology to produce the Powerwall which has been installed in many homes.The Powerwall is a home battery that can power an entire home, including TV, air conditioner, lights, etc. The SE7680 Powerwall can be used with electricity, So it can be adjusted to allow users to store electricity when demand is low for use during peak times.

Max Efficiency Up To 93%

Emergency Power Supply

Wall-mounted Or Stand

246357

High voltage LFP Battery

Longer Life Cycle Time

Smart Cooling Technology

Reduce Your Energy Bills

See How It Works In The Home

In self-powered mode, the SE7680 Powerwall can store the electricity generated by the rooftop solar system during the day and allows users to store electricity converted from the solar panels, so that even after the sun goes down, previous collection can also be used. As a backup battery, one of the main functions of the Powerwall is to provide backup power in the event of a mains power outage.

23 (1)
23 (1)

Your System At Your Fingertips

Remote Monitoring

With the iSPACE application, you can accurately monitor your electricity consumption or generation anytime, anywhere. iSPACE offers a variety of options for observing, analyzing, or controlling energy balance via the Internet on a PC or an application on a smartphone or pad.

Works Day and Night

Powerful Storage

Solar panels are great money-savers whilst the sun shines, but by adding a iSPACE SE7680 Powerwall to your existing solar system, you can store that valuable free energy and use it whenever you want - even at night.

23 (2)
Viewing Technical Specifications
Model Name SE2650Wh SE7680Wh  SE9600Wh SE14400Wh
Powerwall System Parameters
Dimensions(L*W*H) 593*195*950mm 600mm*195mm*1200mm 600mm*195mm*1400mm 600mm*350mm*1200mm
Rated energy ≥2.56kWh ≥7.68kWh ≥9.6kWh ≥14.4kWh
Charge current 0.5C 0.5C 0.5C 0.5C
Max. discharge current 1C 1C 1C 1C
Cut-off voltage of charge 29.2V 58.4V 58.4V 58.4V
Cut-off voltage of discharge 20V@>0℃ / 16V@≤0℃ 20V@>0℃ / 16V@≤0℃ 40V@>0℃ / 32V@≤0℃ 40V@>0℃ / 32V@≤0℃
Charge temperature 0℃~ 60℃ 0℃~ 60℃ 0℃~ 60℃ 0℃~ 60℃
Discharge temperature -20℃~ 60℃ -20℃~ 60℃ -20℃~ 60℃ -20℃~ 60℃
Storage ≤6 months:-20 ~ 35 °C, 30%≤SOC≤60%
≤3 months:35~45 ℃,30%≤SOC≤60%
≤6 months:-20 ~ 35 °C, 30%≤SOC≤60%
≤3 months:35~45 ℃,30%≤SOC≤60%
≤6 months:-20 ~ 35 °C, 30%≤SOC≤60%
≤3 months:35~45 ℃,30%≤SOC≤60%
≤6 months:-20 ~ 35 °C, 30%≤SOC≤60%
≤3 months:35~45 ℃,30%≤SOC≤60%
Cycle life@25℃,0.25C ≥6000 ≥6000 ≥6000 ≥6000
Net weight ≈59kg ≈100kg ≈130kg ≈160kg
Inverter Specification
SUNTE Model Name SE2650Wh SE7680Wh  SE9600Wh SE14400Wh
PV String Input Data
Max. DC Input Power (W) 2000 6400 6400 6400
MPPT Range (V) 120-380 125-425 125-425 125-425
Start-up Voltage (V) 120 100±10 100±10 100±10
PV Input Current (A) 60 110 110 110
No.of MPPT Trackers 2 2 2 2
No.of Strings Per MPPT Tracker 1+1 1+1 1+1 1+1
AC Output Data
Rated AC Output and UPS Power (W) 1500 3000 5000 5000
Peak Power (off grid) 2 times of rated power, 10 S 2 times of rated power, 5 S 2 times of rated power, 5 S 2 times of rated power, 5 S
Output Frequency and Voltage 50 / 60Hz; 120 / 240Vac (split phase), 208Vac (2 / 3 phase), 230Vac (single phase) 50 / 60Hz; 110Vac(split phase)/240Vac (splitphase), 208Vac (2 / 3 phase), 230Vac (single phase) 50 / 60Hz; 110Vac(split phase)/240Vac (splitphase), 208Vac (2 / 3 phase), 230Vac (single phase) 50 / 60Hz; 110Vac(split phase)/240Vac (splitphase), 208Vac (2 / 3 phase), 230Vac (single phase)
Grid Type Single Phase Single Phase Single Phase Single Phase
Current Harmonic Distortion THD<3% (Linear load<1.5%) THD<3% (Linear load<1.5%) THD<3% (Linear load<1.5%) THD<3% (Linear load<1.5%)
Efficiency
Max. Efficiency 93% 93% 93% 93%
Euro Efficiency 97.00% 97.00% 97.00% 97.00%
MPPT Efficiency >98% >98% >98% >98%
Protection
PV Input Lightning Protection Integrated Integrated Integrated Integrated
Anti-islanding Protection Integrated Integrated Integrated Integrated
PV String Input Reverse Polarity Protection Integrated Integrated Integrated Integrated
Insulation Resistor Detection Integrated Integrated Integrated Integrated
Residual Current Monitoring Unit Integrated Integrated Integrated Integrated
Output Over Current Protection Integrated Integrated Integrated Integrated
Output Shorted Protection Integrated Integrated Integrated Integrated
Output Over Voltage Protection Integrated Integrated Integrated Integrated
Surge protection DC Type II/AC Type II DC Type II / AC Type II DC Type II / AC Type II DC Type II / AC Type II
Certifications and Standards
Grid Regulation UL1741, IEEE1547, RULE21, VDE 0126,AS4777, NRS2017, G98, G99, IEC61683,IEC62116, IEC61727
Safety Regulation IEC62109-1, IEC62109-2
EMC EN61000-6-1, EN61000-6-3, FCC 15 class B
General Data
Operating Temperature Range (℃) -25~60℃, >45℃ Derating
Cooling Smart cooling
Noise (dB)
Communication with BMS RS485; CAN
Weight (kg) 32
Protection Degree IP55
Installation Style Wall-mounted/Stand
Warranty 5 years

*More models are also available.